Another fire suppression system ideal for data center use is clean agent fire suppression systems like the FM-200. Fires are made up of heat, oxygen, and a fuel source. Eliminating one of these elements will extinguish a fire and stop its spread. The FM-200 uses a chemical gas known as hydrofluorocarbon or HFC.
When considering fire in a data center, fuel is anything that has the capability to catch fire, such as servers, cables, cardboard boxes or flooring. A heat source is necessary for ignition to occur and different materials have different ‘flashpoints’ or the lowest temperatures at which they can ignite.
3 Levels of Data Center Fire Protection Standards
It is important to note that only specific types of gaseous agents can be used in data center fire extinguishers. HFC-236fa is a gaseous agent specific to fire extinguishers, that has been approved for use in data centers. It is environmentally safe and can be discharged in occupied areas.
People Also Ask what is used in data centers for fire extinguishers
What is the best fire extinguisher for data centers?
HFC-236fa is a gaseous agent specific to fire extinguishers, that has been approved for use in data centers. It is environmentally safe and can be discharged in occupied areas.
What makes total flooding fire extinguishing systems perfect for data centers?
If a fire occurs and the system is activated, the gaseous agent discharges and fills the room in about 10 seconds. One of the best features of this system is that it is able to infiltrate hard to reach places, such as equipment cabinets. This makes Total Flooding Fire Extinguishing Systems perfect for data centers.
What type of fire detector is best for a data center?
For the purposes of protecting a data center, smoke detectors are the most effective. Heat detectors and flame detectors are not recommended for use in data centers, as they do not provide detection in the incipient stages of a fire and therefore do not provide early warning for the protection of high value assets.
What is a fire extinguisher used for?
A fire extinguisher is an active fire protection device used to extinguish or control small fires, often in emergency situations. They are extremely valuable in data centers because they are a quick solution to suppressing fire.
People Also Searches what is used in data centers for fire extinguishers
computer fire extinguisher |
data center fire suppression systems |
fire extinguisher for computer room |
fire extinguisher for server room |
fire extinguisher for electronic equipment |
fire extinguisher for electronics |
fire protection for data centers |
clean room fire extinguisher |
Fire Protection in a Data Centre Video Answer