How should a portable fire extinguisher be selected

When distributing portable fire extinguishers an additional level of complexity is added when walls, obstructions and other structural features that limit movement are taken into consideration. Placement . Extinguishers need …

For more information, see tables 6.2.1.1 and 6.3.1.1 in NFPA 10. The smaller of the required distances between fire extinguishers should be chosen. This is because if each fire extinguisher requires 75 ft. of walking, then the average person may take up to 30 seconds to grab a fire extinguisher when walking 3-4 mph.

How to Select the Right Portable Fire Extinguisher

Portable fire extinguishers should be placed in a very visible location that has an unobstructed view, placed along normal travel paths and …

Also Check:  Why do dogs like to pee on fire hydrants

If an extinguisher weighs less than 40 lbs, the carrying handle should be no more than 5 ft from the ground. Any heavier than 40 lbs and the handle should be no more than 3.5 ft from the floor. These heights reflect the requirement that employees should be able to access a fire extinguisher without risking an injury.

People Also Ask how should a portable fire extinguisher be selected

How do I choose the right fire extinguisher?

The first step is to choose the correct extinguisher based on the fire risk. Extinguishers are broken down into the following ratings: The distribution of portable fire extinguishers is a balance between having an extinguisher nearby when you need it but not being overly burdened by the cost and maintenance of having excessive extinguishers.

Also Check:  Who is responsible for fire hydrants

How much clearance do you need for a portable fire extinguisher?

According to the Extinguisher Placement and Safety page of OSHA’s Evacuation Plans and Procedures eTool, there must be at least four inches clearance between the floor and the bottom of a portable extinguisher.

How many 2 a fire extinguishers are required in a building?

NFPA recommends one 2-A fire extinguisher for every 3,000 square feet. OSHA requires employees to have access to an extinguisher within 75 feet. Employees should have access to a fire extinguisher within either 30 or 50 feet, depending on the hazard in question and the rating of the extinguisher (see below).

Also Check:  Do fire departments give fire extinguishers

What is the distribution of portable fire extinguishers?

The distribution of portable fire extinguishers is a balance between having an extinguisher nearby when you need it but not being overly burdened by the cost and maintenance of having excessive extinguishers. Let us start off with what NFPA 10 Standard for Portable Fire Extinguishers requires.

People Also Searches how should a portable fire extinguisher be selected

osha fire extinguisher training pdf
fire extinguisher use pdf
fire extinguisher how to operate
fire extinguisher instructions
basic fire extinguisher training
how to use a fire extinguisher handout
fire extinguisher toolbox talk pdf
fire extinguishers safety training handout

Portable Fire Extinguisher Selection Video Answer


Reference:
https://www.usfa.fema.gov/
https://en.wikipedia.org/wiki/Fire_extinguisher